QUESTION:
Under the civil-engineering design of three multi-storey houses at us application of foam concrete (bulk and block) is planned. It is necessary 30-40 m3 in change (8 hour.). Purchase will cost what cost at you the equipment (shipment at own expense) and what completeness of this equipment for us?
THE ANSWER:
Completeness: foam generator, foam generator, the compressor, 2 bunkers under cement and sand, tensor gauges, the distributing machine, overpass for the equipment, the form under foam blocks - 30 piece on 1.5 m3. A total cost of the equipment - 196000 hrn. Our technologist more in detail can tell about advantages of our equipment.
QUESTION:
Whether prompt, please, it is possible to do internal and external walls of foam concrete?
THE ANSWER:
It is possible to do internal carrying walls of foam concrete, external too it is possible if to revet
QUESTION:
Specify, please, cost forms for manufacturing foam blocks, and their quantity{amount} for adjustment of manufacture for installation 2 m3 / hour.
THE ANSWER:
6-7 forms are necessary for adjustment of such manufacture on 1.5?3. Cost of one such form on 42 blocks in the size 600?300?200 - 3900 hrn. Under condition of the order for all 7 forms.
QUESTION:
Tell, please, you give what documents on the sold equipment?
THE ANSWER:
We give the project THAT, those. The rules, the operation manual, sanctions a dignity. Stations and firemen.
QUESTION:
Prompt, please, what total cost of installation on manufacture foam isol productivity 63/hour?
THE ANSWER:
Cost of the equipment 8785 hrn. Probably separate purchase of the technical and technological documentation, assembly drawings.
QUESTION:
Tell, please, whether it is necessary for manufacture foam isol water 50? or it is possible to apply and cold water?
THE ANSWER:
Necessarily, it is stipulated those. The rules
QUESTION:
Specify the sizes foam concrete, foam and polyurethane blocks
THE ANSWER:
The sizes different, depending on forms. The standard block of foam concrete - 600x300x200 mm, foam isol - 1000x1000x50 mm, polyurethane - the different sizes
QUESTION:
Whether manufacturing on your equipment of sheet polyfoam for external warming walls of houses is possible?
THE ANSWER:
Sheets on our equipment to make it is possible, but they should be placed between two protective designs. Components foam isol: Pitch КФМТ-15, orthophosphate an acid, foamer, water.
QUESTION:
Whether it is possible to warm foam isol a mansard part of a roof? What problems and so forth inconveniences thus can arise?
THE ANSWER:
Roof to warm it is possible. It is important, that foam isol was in the middle between two layers of other building materials.
|
|
|